Carling Technologies
Carling Technologies is one of the world's largest manufacturers of Hydraulic Magnetic and Thermal Circuit Breakers, Electrical Switches and Assemblies, and Advanced Systems including Power Distribution Centers, Digital Switching Systems, and Electronic Controls.

 

 

 

1.Switches 
Rocker Switches
Part Description
610/620-Series miniature non-illuminated insulated snap-in rocker/paddle switch; single or double pole, double insulated; .4 VA @ 20V, 2 to 8 amp, 125 to 250 VAC; UL, CSA
611/621-Series miniature non-illuminated insulated snap-in rocker/paddle switch; single or double pole; double insulated; two color Visi-Rocker option; .4 VA @ 20V, 2 to11 amp, 125 to 250VAC; UL, CSA, VDE
622/632-Series miniature illuminated and non-illuminated snap-in rocker switch; single and double pole; 8 to 16 amp, 125 to 250VAC; 100 amp peak inrush capability; LED, incandescent, neon lamps; UL, CSA
651/652-Series miniature non-illuminated snap in rocker switch; single pole, "shallow base" fitting standard .508 x .756 rectangular cut out; .4VA @ 28V resistive, 6 to 12 amp, 125 to 250VAC; UL, CSA
LRGSC-Series illuminated double pole snap-in rocker switch; clear or translucent actuators; 15 to 20 amp, 125 to 250VAC; 125 amp peak inrush capability; low voltage ratings; incandescent or neon lamps; UL, CSA
LR-Series illuminated single pole miniature snap-in rocker/paddle switch; clear or translucent actuators, 10 to 16 amps, 125 to 250 VAC; low voltage ratings; incandescent or neon lamps; UL, CSA, VDE, TUV (and more)
LTA-Series illuminated single pole snap-in rocker/paddle switch; 5 to 20 amp, 125 to 250VAC; incandescent and neon lamps; UL, CSA
RGSC-Series non-illuminated double pole snap-in rocker/paddle switch; solid color actuators, 6 to 20 amp, 125 to 277 VAC; 125 amp peak inrush capability; UL, CSA
RSC-Series non-illuminated single pole snap-in rocker switch; two color Visi-Rocker option, 15 to 20 amp, 125 to 250 VAC; 125 amp peak inrush capability; UL, CSA
R-Series non-illuminated single pole miniature snap-in rocker/paddle switch; two color Visi-Rocker option, 5 to 16 amp, 125 to 250 VAC; UL, CSA, VDE, TUV (and more
T-Series non-illuminated single pole rocker snap-in rocker/paddle switch; 5 to 20 amp, 125 to 250VAC; UL, CSA
LS-Series Drip Dry Softspot illuminated single pole snap-in rocker switch; three color high brightness lighting sequence; 10 to 15 amp, 125 to 250VAC, incandescent and neon lamps
LTIG-Series Full size Tippette illuminated double pole rocker switch; 3 to 15 amp, 125 to 250VAC; various actuator styles; snap-in or screw mount; various bracket options including watershedding; incandescent and neon lamps; UL, CSA
LTIH-Series Full size Tippette illuminated three pole rocker switch; 3 to 15 amp, 125 to 250VAC; various actuator styles; snap-in or screw mount; various bracket options; incandescent and neon lamps; UL, CSA
LTIL-Series Full size Tippette illuminated single pole rocker switch; 3 to 17 amp, 125 to 250VAC; various actuator styles; snap-in or screw mount; various bracket options including watershedding; incandescent and neon lamps; UL, CSA
RR/LRR-Series illuminated or non-illuminated round rocker switch; single pole; 10 to 12 amp, 125 to 250VAC; Led, neon, incandescent lamps; UL, CSA Approvals
TG, LTG-Series illuminated and non-illuminated snap-in rocker/paddle switch; single or double pole; 5 to 15 amp, 125 to 250VAC; incandescent and neon lamps; UL, CSA, VDE
TIL,TIG, TIH, TII-Series Full size non-illuminated rocker switch; 1 to 4 poles; 3 to 20 amp, 125 to 250VAC; various actuator styles, snap-in or screw mount; various bracket options including watershedding; UL, CSA, VDE
TLG-Series single pole snap-in rocker/paddle switch with adjacent indicator light; 5 to 20 amp, 125 to 250VAC; incandesent and neon lamps; UL, CSA
TTG-Series illuminated and non-illuminated snap-in rocker/paddle switch; two single pole switches in a common base; each pole can have the same or different function; 5 to 20 amp, 125 to 250VAC; incandescent or neon lamps; UL, CSA
J-Series sealed illuminated or non-illuminated rocker switch; single or double pole, IP66 & IP68 certified, 10 amp, 12V or 24V;flush or raised bracket, one or two-piece lenses
LD-Series sealed illuminated or non-illuminated rocker; 4A - 10A @ 12V, 2A-5A@24V; multiple dimming rate options, laser-etched legends, LED lamps; industry standard mounting hole
L-Series sealed illuminated or non-illuminated rocker switch; single or double pole; IP67 certified; .4VA @ 28VDC Resistive, 15-20 amp, 3V-24V; laser etched legends, incandescent and LED lamps; industry standard mounting hole; locking actuator option
VP-Series Illuminated Plug; neon, incandescent, or LED lamps; two piece snap-in lenses; removable lamp module; flush, raised panel, oval housing styles; vibration, shock & thermoshock resistant
V-Series: Contura X, XI & XII heavy duty sealed illuminated or non-illuminated rocker/paddle switch; single or double pole, IP66 & IP68 certified, 10 to 20 amp,125 to 250VAC; UL, CSA, VDE (and more); flush or raised bracket, one or two-piece lenses, locking actuator option
V-Series: Contura IV & V heavy duty sealed illuminated or non-illuminated rocker switch; single or double pole; Shape-to-create-a-shape rockers; IP66 & IP68 certified, 10 to 20 amp,125 to 250VAC; UL, CSA, VDE (and more); flush bracket, locking actuator option
V-Series: Contura II & III heavy duty sealed illuminated or non-illuminated rocker switch; single or double pole; IP66 & IP68 certified, 10 to 20 amp,125 to 250VAC; UL, CSA, VDE (and more); flush bracket, locking actuator option
W-Series fully sealed illuminated or non-illuminated rocker switch; single or double pole; IP68 certified, 10 amp, 3 to 24V; flush bracket, curved rocker & locking rocker actuator options
Toggle Switches
110/216-Series single & double pole toggle switch; quick-make, quick-break; 1 to 10 amp, 125 to 250VAC; bushing mount; UL, CSA
C-Series single pole toggle switch; 5 to 20 amp, 125 to 250VAC; bushing mount; UL, CSA
DK/EK-Series heavy duty single & double pole toggle switch; quick-make, quick-break; 8 to 20 amp, 125 to 250VAC; bushing mount; UL, CSA
D-Series all nylon single pole toggle switch; 3 to 20 amp, 125 to 250VAC; bushing mount; UL, CSA
F-Series single pole toggle switch; slow-make, slow-break; 3 to 15 amp, 125 to 250VAC; bushing mount; UL, CSA
G-Series double pole toggle switch; slow-make, slow-break; 3 to 20 amp, 125 to 277VAC; metal and plastic decorator toggle options; bushing mount; UL, CSA, VDE
H-Series heavy duty three pole toggle switch; slow-make, slow-break; 3 to 17 amp, 125 to 600VAC; metal and plastic decorator toggle options; bushing mount; UL, CSA
I-Series heavy duty four pole toggle switch; slow-make, slow-break; 10 to 15 amp, 125 to 250VAC; metal and plastic decorator toggle options; bushing mount; UL, CSA ; slow-make, slow-break; 3 to 17 amp, 125 to 600VAC; metal and plastic decorator toggle options; bushing mount; UL, CSA
LT-Series illuminated toggle/paddle switch; single and double pole; 3 color lighting sequence, 10 to 15 amp, 125 to 250VAC; neoprene sealing; incandescent and neon lamps
MAAOA/215-Series high temperature single pole snap-in toggle switch; 10 to 20 amps, 125 to 250VAC; UL, CSA
Push Button Switches
110/316P-Series heavy duty single and double pole pushbutton switches; 1 to 10 amps, 125 to 250VAC; 6-8 lbs. actuation force, quick-make, quick-break; bushing mount; UL, CSA
16-3P-Series light action single pole pushbutton switch; 1 to 3 amps, 125VAC; .4oz to 1 lb. actuation force, slow-make, slow-break; bushing mount; UL, CSA
170/172-Series heavy action single pole pushbutton switch; 10 to 15 amps, 125 to 250VAC; 2.5 lb actuation force, slow-make, slow-break; UL, CSA
641-Series single and double pole pushbutton switches; 2 to 5 amps, 125 to 250VAC; 3 to 3.5 lbs actuation force, slider contact; bushing mount; UL, CSA
P26-Series medium action single pole momentary pushbutton switches; 1 to 8 amps, 125 to 277VAC; 13 oz. actuation force, slow-make, slow-break; bushing mount; UL, CSA
P27-Series medium action single pole momentary pushbutton switches; 3 to 6 amps, 125 to 250VAC; 26 oz. actuation force, slow-make, slow-break; nylon concave pushbutton; bushing mount; UL, CSA
PP-Series heavy duty single pole plastic pushbutton switch; 10 to 15 amps, 125 to 250VAC; wire leads; bushing mount; UL, CSA
P-Series heavy duty single pole pushbutton switch; 10 to 20 amps, 125 to 250VAC; alternate action; bushing mount; UL, CSA
Rotary Switches  
700-Series four position single pole rotary switch; 1 to 4 amp, 125 to 250VAC; self-cleaning wiping contacts; bushing mount; UL, CSA
800-Series eight position single pole rotary switch; 3 to 8 amp, 125 to 250VAC; self-cleaning wiping contacts; bushing mount; UL, CSA
R135-Series single pole single throw repeating action rotary switch; 1.5 to 5 amp, 125 to 250VAC; "L" rated up to 3 amp; snap-in or bushing mount; UL, CSA
Miniature & Sub-mini Switches
1M-Series miniature, sealed and non-sealed, non-illuminated, rocker & paddle switch; 1-4 poles; .4 VA @ 20V, 2 to 5 amp, 125 to 250 VAC or 28VDC; UL, CSA, CUL, IP67; PC, PCB, solder lug, quick connect, wire wrap, & snap-in mount
1S-Series sub-miniature, sealed and non-sealed, non-illuminated, rocker switch; single or double pole; .4 VA @ 20V, 1.5 to 3 amp, 125 to 250 VAC or 28VDC; UL, CSA, IP67; PC, PCB, snap-in, & surface mount
2M-Series miniature, sealed and non-sealed, non-illuminated, toggle switch; 1-4 poles; .4 VA @ 20V, 2 to 5 amp, 125 to 250 VAC or 28VDC; UL, CSA, CUL, IP67; PC, PCB, solder lug, quick connect, wire wrap, & snap-in mount
2S-Series sub-miniature, sealed and non-sealed, non-illuminated, toggle switch; single or double pole; .4 VA @ 20V, 1.5 to 3 amp, 125 to 250 VAC or 28VDC; UL, CSA, IP67; PC, PCB, solder lug, snap-in, & surface mount
3M-Series miniature, sealed and non-sealed, non-illuminated, pushbutton switch; 1-4 poles; .4 VA @ 20V, 1 to 6 amp, 125 to 250 VAC or 28VDC; UL, CUL, IP68; PC, PCB, solder lug, wire wrap, & snap-in mount
3S-Series sub-miniature, sealed and non-sealed, non-illuminated, pushbutton switch; single or double pole; .4 VA @ 20V, 1 amp, 125 VAC or 28VDC; IP67; PC, PCB, solder lug, snap-in, & surface mount
4PM-Series sub-miniature & miniature, sealed and non-sealed, non-illuminated; slide switch; 1-2 poles; .4 VA @ 20V, 1.5 to 5 amp, 125 to 250 VAC or 28VDC; UL, CSA; PC, PCB, solder lug, quick connect, wire wrap, & surface mount
4S & 4M-Series miniature, non-illuminated, slide switch; 1-2 poles; 0.1 A @ 30VDC, 2 amp, 250 VAC; PCB mount
2.Circuit Protection 
Hydraulic/Magnetic Circuit Breakers
A-Series hydraulic/magnetic circuit breaker; Snap-in mounting; Handle actuator; 1-6 poles; Rocker actuator, 1-3 poles; 0.02-50 amps, up to 277VAC or 65VDC; UL, CSA, UL1500
B-Series hydraulic/magnetic circuit breaker; Handle actuator; 1-6 poles; 0.02-50 amps, up to 277VAC or 80VDC; UL, CSA, VDE-0642, TUV, UL1500, UL489A Listed (Telecom). UL489 up to 30 amps, 120/240 VAC
  •Rocker actuator, 1-3 poles, UL489 Listed up to 30 amps, 120/240VAC
C-Series Remote Operated Circuit Breaker; Handle actuator, 1-3 poles, 0.02-100 amps, up to 480VAC or 80VDC; UL, CSA, UL489, TUV, UL 1500
C-Series hydraulic/magnetic circuit breaker; Handle actuator; 1-6 poles; 0.02. -100 amps, up to 480VAC or 80VDC; UL, CSA, VDE, UL1500
  • Rocker actuator; 1-3 poles, 0.02-100 amps, up to 480VAC or 80VDC; UL, CSA, VDE, TUV, UL1500
  • UL489; Handle/Rocker actuator; 1-6 poles, 0.10-100 amps, up to 240VAC or 125VDC; UL489, UL489A Listed (Telecom
D-Series Din Rail hydraulic/magnetic circuit breaker; Handle actuator; 1-4 poles; 0.02-50 amps, up to 480VAC or 80VDC; UL, CSA, VDE
E-Series hydraulic/magnetic circuit breaker; Handle actuator; 1-6 poles; 0.10-100 amps, up to 600VAC or 125VDC; UL, CSA, UL489, VDE (240VAC max.)
F-Series high amperage hydraulic/magnetic circuit breaker; Handle actuator; 1-3 poles; 100-700 amps, 125VDC; UL489, UL489A (Telecom), CUL Certified, TUV
M-Series miniature hydraulic/magnetic circuit breaker; Handle actuator; illuminated or non-illuminated; snap-in mounting; 1-2 poles; 0.02-30 amps, up to 250VAC or 80VDC; UL, CSA, VDE, TUV, UL489A
Thermal Circuit Breakers
C1005B-Series Rocker actuator; front panel snap-in mount; single pole; non-lighted and lighted 125 or 250VAC; 7-16 amps, up to 250VAC; 32VDC; UL, CSA, TUV, UL1077, UL1363, IEC 60934
CLB-Series Push-to-reset pushbutton actuator; front panel or front panel snap-in mount; single pole; 3-60 amps, up to 250VAC; 32VDC; UL, CUL, TUV, CE, UL1500/ISO 8846 for ignition protectio
CMB-Series Push-to-reset pushbutton actuator; front panel or front panel snap-in mount; single pole; 3-20 amps, up to 250VAC; 32VDC; UL, CSA, TUV, CE, UL1500/ISO 8846 for ignition protection.
CTB-Series Rocker actuator; front panel snap-in mount; single pole; 3-16 amps, up to 250VAC; 50VDC; UL, CUL, VDE, CE
Equipment Leakage & Ground Fault Circuit Breakers
PB-Series Overcurrent & Ground Fault Protection; Handle & Rocker actuator;; Handle & Rocker actuator; 1-3 poles where 3rd pole is neutral; front panel mount; 0.10 -30 amps, up to 240VAC; UL489, CSA, UL1077, UL1500
PC-Series Overcurrent & Ground Fault Protection;; Handle, Rocker, Flat Rocker, Push-to-Reset actuators; LED indication for overcurrent or leakage current events; 1-3 poles; front panel mount; 0.10 -50 amps, up to 240VAC; UL943, UL1053, UL1500
PD-Series SmartGuard equipment leakage circuit breaker; Handle actuator; front panel or Din rail mounting; equipment ground fault protection; 1-3 poles; switched or unswitched neutral options; 1-50 amps, up to 480Y/277VAC; 7-100 milliamp equipment leakage trip current; LED leakage trip indicator; UL, CSA
3.Power Distribution Centers 
Standard AC
LAC1-Series Telecom AC Power Distribution Center; UL67 listed for AC panelboards, from 120-240VAC, wall mounted enclosure 20" W x 14"H x 3.84" D.
Standard DC
LDC1-Series DC Power Distribution Center; designed to fit 19" rack systems. This 1 RU is UL/CUL 1801 listed and designed to EN60950. C his 1 RU is UL/CUL 1801 listed and designed to EN60950. Panel utilizes UL489 listed hydraulic-magnetic circuit breakers.
LDC2-Series DC Power Distribution Center; designed to fit 23" rack systems, and combines GMT fuse protection with hydraulic-magnetic circuit breaker protection, powerful dual feed redundancy for both circuit breakers and fuses.
LDM1-Series DC Power Distribution Center; designed to fit 19" rack systems, UL/CUL 1801 listed and designed to EN60950, contains miniature M-Series hydraulic-magnetic breakers - the smallest breaker on the market that is UL489A listed up to 80VDC
Standard Disconnect
LBD-Series Battery Disconnect Panels; ratings up to 700 amps and an interrupting capacity of 50,000A @ 125VDC, available in sizes as small as 1RU x 19" up to 3RU.